Newsprint Pulp De-Inked - Manitoba

  • Activated sludge treatment with selector tank
  • Flow - 8 MGD (30,000 M3)
  • Design BOD5 load of 66,000 lb/day (30,000 kg/day)
  • Actual treated BOD5 of 68,000 lb/day (31,000 kg/day)
  • One aeration tank 200 ft (61 M) diameter
  • One selector tank 54 ft (16.5 M)diameter
  • 26 ft (8 M) deep
  • Total tank volume - 6.3 million gallons (24,000 M3)
  • Five directional mix jet aerators
  • Five 100 HP pumps
  • Four 300 HP air blowers
  • Selector tank can be operated in aerobic or anaerobic mode
  • The system achieves 98% BOD5 removal

 

DMJA

One directional mix jet aerator was installed
in the selector tank.

Plan view

Plan view of the aeration and selector tanks.