CASE HISTORIES

Pulp and Paper Mill - Ontario

  • Activated sludge treatment
  • Flow - 6 MGD (23,000 M3)
  • Design BOD5 load of 20,000 lb/day (9,000 kg/day)
  • Actual treated BOD5 of 68,000 lb/day (31,000 kg/day)
  • 130 ft (40 M) diameter
  • 27 ft (8.2 M) deep
  • Tank volume - 3 million gallons (12,000 M3)
  • Four directional mix jet aerators
  • Four 40 HP pumps
  • Two 200 HP air blowers
  • system consists of an anoxic selector tank followed by activated sludge tank.
  • Anoxic selector tank minimizes filamentous bacteria.
  • System achieves 98% BOD5 removal

 

DMJAs

Four directional mix jet aerators completely
mix the entire tank contents.

Plan view

Plan view of aeration tank.